Original Paper
Abstract
Background: Septic shock is a low-frequency but high-stakes condition in children requiring prompt resuscitation, which makes it an important target for simulation-based education.
Objective: In this study, we aimed to design and implement an augmented reality app (PediSepsisAR) for septic shock simulation, test the feasibility of measuring the timing and volume of fluid administration during septic shock simulation with and without PediSepsisAR, and describe PediSepsisAR as an educational tool. We hypothesized that we could feasibly measure our desired data during the simulation in 90% of the participants in each group. With regard to using PediSepsisAR as an educational tool, we hypothesized that the PediSepsisAR group would report that it enhanced their awareness of simulated patient blood flow and would more rapidly verbalize recognition of abnormal patient status and desired management steps.
Methods: We performed a randomized controlled feasibility trial with a convenience sample of pediatric care providers at a large tertiary care pediatric center. Participants completed a prestudy questionnaire and were randomized to either the PediSepsisAR or control (traditional simulation) arms. We measured the participants’ time to administer 20, 40, and 60 cc/kg of intravenous fluids during a septic shock simulation using each modality. In addition, facilitators timed how long participants took to verbalize they had recognized tachycardia, hypotension, or septic shock and desired to initiate the sepsis pathway and administer antibiotics. Participants in the PediSepsisAR arm completed a poststudy questionnaire. We analyzed data using descriptive statistics and a Wilcoxon rank-sum test to compare the median time with event variables between groups.
Results: We enrolled 50 participants (n=25 in each arm). The timing and volume of fluid administration were captured in all the participants in each group. There was no statistically significant difference regarding time to administration of intravenous fluids between the two groups. Similarly, there was no statistically significant difference between the groups regarding time to verbalized recognition of patient status or desired management steps. Most participants in the PediSepsisAR group reported that PediSepsisAR enhanced their awareness of the patient’s perfusion.
Conclusions: We developed an augmented reality app for use in pediatric septic shock simulations and demonstrated the feasibility of measuring the volume and timing of fluid administration during simulation using this modality. In addition, our findings suggest that PediSepsisAR may enhance participants’ awareness of abnormal perfusion.
doi:10.2196/29899
Keywords
Introduction
Background
Augmented reality (AR) and virtual reality (VR) have been increasingly explored as tools for innovation in medical education in both medical and surgical subspecialties [
- ]. VR refers most broadly to the digital representation of an immersive world, whether novel or realistic [ , ]. In contrast, AR projects a digital overlay onto the physical environment, emphasizing task performance in the real world that is augmented by virtual elements [ ]. AR and VR may be experienced through head-mounted displays using mobile devices or computers. In recent years, AR- and VR-based activities have become increasingly easy to scale and distribute widely [ , ].AR and VR have been used most frequently for surgical training [
- ], anatomical study [ - ], and cardiopulmonary resuscitation (CPR) training [ - ]. To date, there is a relative dearth of studies exploring the incorporation of AR into medical resuscitation scenarios [ , , ]. Studies evaluating AR enhancement of simulated procedural training indicate that learners respond favorably to its use [ - ]. In a recent medical simulation study, participants recognized shock and clinical decompensation significantly sooner when using AR. These findings suggest the potential of AR to improve clinical care at the bedside [ ].Simulation has been shown to enhance retention of resuscitation skills [
]; pediatric care providers particularly benefit from simulation-based resuscitation exercises, as real-life resuscitation events are rare in children [ , ]. However, even high-fidelity simulations are limited in their capacity to replicate real-life scenarios. These challenges are highlighted in the case of sepsis, a potentially life-threatening response to infection. In children with potential sepsis, clinicians need to make rapid clinical decisions [ ], and these decisions are often based on physical examination findings that are difficult to simulate on a mannequin. Time to recognize septic shock and administrate antibiotics and intravenous fluids are all linked to improved outcomes in pediatric patients with septic shock [ ]. For this reason, many hospitals have implemented recognition systems and care pathways to ensure rapid, standardized, and high-quality care for children in septic shock; our institution’s sepsis pathway is one example. By providing a means of visualizing perfusion during simulation, AR can potentially enhance simulation participants’ abilities to make timely and realistic management decisions about patients in septic shock.Objective
In this study, we aimed to create an AR representation of impaired perfusion (PediSepsisAR) and incorporate this app into a pediatric septic shock simulation. Our primary aim was to determine the feasibility of collecting data on the timing and volume of fluid administrated during septic shock simulation with and without the use of PediSepsisAR. We hypothesized that we would be able to measure the timing and volume of fluid administration in 90% of the participants. A second exploratory aim was to describe PediSepsisAR as an educational tool in septic shock simulation. Specifically, we aimed to compare control and PediSepsisAR participants’ timing of stated recognition of shock and desired management steps and elicit participant attitudes toward the experience of using PediSepsisAR during septic shock simulation. We hypothesized that PediSepsisAR participants would sooner state shock recognition and express desired management steps—administering antibiotics and initiating the sepsis pathway. In addition, we hypothesized that participants would report that PediSepsisAR enhanced their awareness of the simulated patient’s perfusion; therefore, the use of the app would have made them want to administer fluids more quickly.
Methods
Theoretical Framework
In designing and studying PediSepsisAR, we considered two main underlying principles: real-time feedback and gamification. Studies have demonstrated improved CPR performance in both simulated and real-life resuscitations using CPR feedback devices [
, ]. By adding PediSepsisAR to a traditional septic shock simulation, we hoped to convey a visual representation of poor perfusion that participants could monitor for improvements as they administered fluids. Real-time feedback is closely tied to the gamification of simulation exercises. Specifically, Rutledge et al [ ] define gamification as the addition of a design element to an existing learning activity to facilitate achieving the activity’s goals. In this manner, PediSepsisAR can be viewed as an element applied to septic shock simulation that provides a dynamic visual representation of the simulated patient’s circulation. PediSepsisAR provides ongoing real-time feedback on the participants’ progress toward the goal of fluid resuscitating the simulated patient; thus, it facilitates the achievement of the goal and gamifies the simulation.Study Setting
This study was conducted in the pediatric emergency department of a large tertiary care academic children’s hospital from October 10 to November 12, 2020.
Study Participants
We enrolled a convenience sample of 50 participants, including pediatric residents, pediatric emergency medicine (PEM) fellows, PEM attending physicians, nurse practitioners, and pediatric nurses, who regularly practice at the pediatric emergency department in the study hospital. Participants were recruited via a combination of email and in-person communication. Written informed consent was obtained from all participants.
Study Design
This study consisted of a nonblinded, randomized, controlled trial design.
Prototype Design
Through a partnership with BrickSimple, LLC, a Philadelphia-based software company, we adapted an existing prototype, CPReality [
, ], to create PediSepsisAR. CPReality integrates with the first-generation Microsoft HoloLens headset and allows for the depiction of a digital model of the circulatory system that can be overlaid on a simulation mannequin. CPReality integrates data from actual CPR performance on a mannequin to create a digital image of the patient’s circulation, which allows participants to visualize the effect of their chest compressions on perfusion during CPR. Our aim in adapting this prototype was to enable our participants to visualize a model of impaired perfusion during fluid resuscitation in a simulated patient with septic shock. Initially, the vessels most proximal to the heart are illuminated, demonstrating that peripheral perfusion is limited ( ); after 20, 40, and 60 cc/kg of fluid boluses are administered, perfusion spreads distally until it ultimately reaches the brain and most peripheral tissues. A demonstration of the circulation expansion is shown in .We worked with BrickSimple to enable PediSepsisAR to interact with a potentiometer embedded in an intravenous fluid syringe. A potentiometer is a variable resistor that linearly restricts low amounts of electricity that can then be translated into an electrical signal. A linear slide potentiometer was chosen specifically because the sliding effect fits well with the mechanical action of pushing a plunger. Team members fit the potentiometer into a 60-cc syringe and then attached the moving part of the device (Wiper) to the syringe plunger so that it would move in a relative fashion depending on how far the plunger was depressed. The position of the plunger could be measured against time to measure the rate of fluid bolus administration.
Once the potentiometer was developed, it was necessary to ensure its ability to communicate with the HoloLens. This was achieved via a wireless connection. More specifically, the potentiometer is connected via USB to a computer running a custom app called Syringe Relay. The HoloLens app that provides the visuals also spins up a transmission control protocol or IP server. The Syringe Relay then connects to the transmission control protocol or IP server and uses it to send data to the HoloLens. The communication sequence is as follows: the potentiometer sends data to the Syringe Relay via the USB; the Syringe Relay app then processes and forwards the data to the HoloLens via a wireless connection. This sequence is shown in
.For the flow of communication to work properly, both the HoloLens and computer must be on the same wireless internet network. When launched, the PediSepsisAR app on the HoloLens continually scans for new connections. The Syringe Relay app is then configured with the current IP address of the HoloLens and can thereby connect to it and send data to it.
All data processing occurred within the Syringe Relay app. First, the app maps the raw potentiometer values to the current milliliter value on the syringe. When the plunger is depressed, it adds the delta to a running total of how many milliliters are infused. The app then converts the total milliliters infused to total mL/kg and sends that value to the HoloLens. The HoloLens then updates the visual display of the perfusion accordingly.
To our knowledge, this is the first study using a potentiometer to measure real-time intravenous fluid administration during simulation.
Study Procedures
All enrolled participants (n=50) completed an electronic prestudy questionnaire. All questionnaire data were collected and managed using REDCap (Research Electronic Data Capture) tools hosted at our institution [
, ]. The prestudy questionnaire was created de novo in conjunction with a coauthor AKW who has expertise in survey question development and is included as a reference in . This questionnaire elicited participants’ demographic data and their report of previous experience with push-pull fluid administration, simulated resuscitations in general, and simulated septic shock. After completing the prestudy questionnaire, each participant opened an envelope containing a number; those participants whose envelope contained even numbers were randomized to the PediSepsisAR group, and those whose envelopes contained odd numbers were randomized to the control group. All participants had the opportunity to practice administering fluids using the push-pull technique ( ) before the simulation exercise. Those randomized to PediSepsisAR then received a short orientation on the HoloLens, which reviewed the proper fit of the HoloLens and provided an example of the visual representation of circulation they would see through the HoloLens.During the consent procedure, participants were informed that the investigators would evaluate their administration of fluids to a simulated patient with septic shock. They were invited to verbalize their assessment of the patient and the management steps they might take in addition to intravenous fluid administration. Before beginning the exercise, all participants received a standardized, short description of the clinical scenario: a previously healthy male aged 15 months presenting with 2 days of fever and 1 day of decreased oral intake and decreased responsiveness. Facilitators gave no further prompts during the simulation. Those randomized to the PediSepsisAR group wore the HoloLens during the simulation; those randomized to the control group completed the simulation without the use of AR. We used the Pediatric HAL (Gaumard) mannequin for all simulations. We measured all participants’ fluid administration using the potentiometer embedded in the 60-cc syringe used to push-pull fluids and recorded the time to administer 20, 40, and 60 cc/kg total administered fluids for the patient’s stated weight. Participants were not directed to administer a specific amount of fluids, and those who chose to stop administering fluids at any point in the simulation were allowed to do so. In addition, the facilitator marked the time that the participant verbalized the following elements of sepsis recognition and treatment: tachycardia or hypotension, sepsis, shock, septic shock, initiation of the sepsis pathway, and intent to administer antibiotics.
Following the simulation exercise, those in the PediSepsisAR group completed an electronic poststudy questionnaire through REDCap asking their opinions about how PediSepsisAR did or did not affect their simulation experience. The poststudy questionnaire was created de novo. Participants had the opportunity to elaborate in a free-text form regarding their answers to the survey questions. The poststudy questionnaire is included in
. All participants received a US $5 coffee shop gift card following their participation.This study was approved by the institutional review board of the Children’s Hospital of Philadelphia. We used Stata 16.0 (StataCorp) for statistical analysis. We assessed the study population using descriptive statistics and compared the median time with the administration of 20, 40, and 60 cc/kg of fluids between each group using the Wilcoxon rank-sum test.
Feasibility Endpoints
We defined the following endpoints a priori as reaching our feasibility goal: (1) We hypothesized that we could feasibly create PediSepsisAR and enable it to interact with a fluid administration system and (2) we hypothesized that we could measure the timing and volume of fluid administration using the potentiometer in at least 90% of the participants. In addition, we hypothesized that for the PediSepsisAR participants, the potentiometer and AR interactivity would function as intended at least 90% of the time.
Results
Overview
We enrolled a total of 50 interprofessional participants, including 6 nurses, 11 nurse practitioners, and 33 physicians at different levels of training: 10 pediatric residents, 13 PEM attendings, and 10 PEM fellows. In total, 25 participants were randomized to the control group, and 25 participants were randomized to the PediSepsisAR group; all disciplines were represented in both the PediSepsisAR and control groups. The demographic characteristics of the study population are shown in
. In the presimulation questionnaire, most participants reported that they had given push-pull intravenous fluids before (21/25, 84% in both groups). Similarly, most participants reported previous experience with septic shock simulation (23/25, 92% in the PediSepsisAR group and 19/25, 76% in the control group). A small minority of participants in either group had previous experience with AR (0/25, 0% in the PediSepsisAR group and 2/25, 8% in the control group).Participants enrolled | PediSepsisAR (n=25), n (%) | Control (n=25), n (%) | |
Study population | |||
Nurse | 4 (16) | 2 (8) | |
Advanced practice provider | 5 (20) | 6 (24) | |
Fellow | 6 (24) | 5 (20) | |
Resident | 5 (20) | 6 (24) | |
Attending | 5 (20) | 6 (24) | |
Clinical experience (years) | |||
1-5 | 6 (24) | 3 (12) | |
6-10 | 8 (32) | 8 (32) | |
>10 | 11 (44) | 14 (56) | |
Ever administered push-pull IVFa | |||
Yes | 21 (84) | 21 (84) | |
No | 4 (16) | 4 (16) | |
Times administered push-pull IVF in the past year | |||
None | 12 (48) | 10 (40) | |
1-5 | 13 (52) | 13 (52) | |
>5 | 0 (0) | 2 (8) | |
Previous simulation experience | |||
Yes | 23 (92) | 25 (100) | |
No | 2 (8) | 0 (0) | |
Septic shock simulation experience | |||
Yes | 23 (92) | 19 (76) | |
No | 2 (8) | 6 (24) | |
Augmented reality experience | |||
Yes | 0 (0) | 2 (8) | |
No | 25 (100) | 23 (92) |
aIVF: intravenous fluid.
Fluid Administration and Verbalization
We measured and recorded the timing of completed administration of 20, 40, and 60 cc/kg of fluids in all participants. In total, 16% (4/25) participants in the PediSepsisAR group experienced the inability to visualize PediSepsisAR initially through the HoloLens; in each instance, the study staff closed and reopened PediSepsisAR on the device, and participants were able to visualize PediSepsisAR after that. All 4 participants subsequently completed the simulation exercise uninterrupted. Participants in the PediSepsisAR group were slightly more likely than those in the traditional group to administer 60 cc/kg of fluid (relative risk 1.2, 95% CI 1.03-1.41). For participants who elected not to give the third bolus, the 60 cc/kg time point was not included. The median time to administration of 20 cc/kg was 117 seconds (IQR 93-154) for the PediSepsisAR group and 134 seconds (IQR 98-161) for the control group (P=.68). For 40 cc/kg, the median time to administration was 265 seconds (IQR 229-363) for the PediSepsisAR group and 284 seconds (IQR 250-350) for the control group (P=.51). Finally, the median time to administration of 60 cc/kg was 419 seconds (IQR 377-536) for the PediSepsisAR group and 468 seconds (IQR 392-524) for the control group (P=.47). These data are presented in
.Fluid bolus | PediSepsisAR (n=25) | Control (n=25) | P value | ||||
Time (seconds), median (IQR) | Participants, n (%) | Time (seconds), median (IQR) | Participants, n (%) | ||||
20 cc/kg | 117 (93-154) | 25 (100) | 134 (98-161) | 25 (100) | .68 | ||
40 cc/kg | 265 (229-363) | 25 (100) | 284 (250-350) | 25 (100) | .51 | ||
60 cc/kg | 419 (377-536) | 25 (100) | 468 (392-524) | 21 (84) | .47 |
In addition to recording the volume and timing of fluid administration, we recorded the points at which participants verbalized recognizing the patient’s condition and expressed the desire to take certain management steps; 92% (23/25) of participants in the PediSepsisAR group and 100% (25/25) of those in the control group verbalized recognizing tachycardia or hypotension. The median time to verbalized recognition was 26 seconds (IQR 6-43) for the PediSepsisAR group and 39 seconds (IQR 10-95) for the control group (P=.20). Regarding the desire to initiate the sepsis pathway, 32% (16/50) of participants verbalized that they would like to start the pathway; this included 20% (5/25) of participants in the PediSepsisAR group and 44% (11/25) of participants in the control group. The median time to verbalize the desire to initiate the sepsis pathway was 96 seconds (IQR 90-133) for the PediSepsisAR group and 136 seconds (IQR 40.5-421) for the control group (P=.67). The data for stated shock, septic shock, or sepsis are as follows: 56% (14/25) of participants in the PediSepsisAR group verbalized one or more of these terms versus 68% (17/25) in the control group. The median time to verbalized recognition of shock, septic shock, or sepsis was 66 seconds (IQR 34-94) for the PediSepsisAR group and 87 seconds (IQR 23.5-192) for the control group (P=.84). In both, the PediSepsisAR and control groups, 84% (21/25) of participants requested antibiotics. Of those who requested antibiotics, the median time to request was 81 seconds (IQR 53-167) for the PediSepsisAR group and 165 seconds (IQR 28-198) for the control group (P=.96). These data are presented in
.Verbalization | PediSepsisAR (n=25) | Control (n=25) | P value | ||
Time (seconds) taken to verbalize, median (IQR) | Participants who verbalized, n (%) | Time (seconds) taken to verbalize, median (IQR) | Participants who verbalized, n (%) | ||
Tachycardia ± hypotension | 26 (6-143) | 23 (92) | 39 (10-95) | 25 (100) | .20 |
Sepsis pathway | 96 (90-133) | 5 (20) | 136 (40.5-421) | 11 (44) | .67 |
Shock, septic shock, or sepsis | 66 (34-94) | 14 (66) | 87 (23.5-192) | 17 (68) | .84 |
Antibiotics | 81 (53-167) | 21 (84) | 165 (28-198) | 21 (84) | .96 |
In the poststudy questionnaire, most participants in the PediSepsisAR group (23/25, 92%) reported that the addition of AR enhanced their awareness of the patient’s blood flow. When asked whether PediSepsisAR made them want to push fluids faster, 56% (14/25) of the PediSepsisAR participants answered that it did. Many participants remarked that PediSepsisAR was distracting (8/25, 32%). In free-text comments, some participants reported that the digital visualization of circulation allowed them to appreciate the patient’s fluid responsiveness in a new way. Some participants commented on the limited field of vision through HoloLens.
Discussion
Principal Findings
In this study, we aimed to design an AR app that could be integrated into a pediatric septic shock simulation and demonstrate the feasibility of its use. Our results demonstrate that it is feasible to record the timing and volume of fluid administration during septic shock simulation both with and without the addition of AR. We hypothesized that we would be able to capture such data in at least 90% of participants in each group and ultimately captured the desired data in all participants.
Our study was not powered to detect significant differences in times of fluid administration between the control and PediSepsisAR groups. We observed that the PediSepsisAR group had a shorter time to fluid bolus administration than the control group. More than half of the participants in the PediSepsisAR group reported that PediSepsisAR made them want to push fluids faster, suggesting that perhaps the components of simulation (provided history, vital signs, and reported delayed capillary refill) alone may encourage rapid fluid administration even without an AR component. Of note, participants in the control group were slightly less likely to administer 60 cc/kg than participants in the PediSepsisAR group. The underlying reason for this observation remains unclear. The changes in simulated patient vital signs with each fluid bolus (20, 40, and 60 cc/kg) were the same for both groups; PediSepsisAR participants showed incompletely improved circulation at 40 cc/kg, whereas the control group participants did not. This suggests that perhaps the additional visualization of perfusion provided through PediSepsisAR informed participants’ awareness of the patient’s status in a way that vital signs alone could not. The question of whether visualizing a digital model of perfusion has an impact on the administration of intravenous fluids during simulation remains and can be explored in future studies.
Our secondary exploratory aim was to describe PediSepsisAR as an educational tool. We explored the educational value of PediSepsisAR in two ways: through comparison of verbalized recognition of patient status and desired management steps in both groups during the simulation exercise and poststudy questionnaires completed by the PediSepsisAR group. We did not find any significant differences in median times to verbalizations of key patient status recognition or management steps, as our study was not powered to detect such a difference. We observed that the time to verbalization of both patient status (abnormal vital signs and shock or septic shock) and requested sepsis pathway initiation and antibiotics were shorter in the PediSepsisAR group than in the control group. This finding suggests that PediSepsisAR may aid the recognition of abnormal fluid status and, in doing so, allow participants to plan management steps more efficiently. Future studies are needed to explore whether the addition of AR impacts the assessment or delivery of care to simulated patients.
The poststudy questionnaire results revealed that most participants perceived that PediSepsisAR enhanced their awareness of the simulated patient’s perfusion. Traditional high-fidelity simulation enables participants to palpate pulses and visualize capillary refill [
], allowing them to assess the simulated patient’s perfusion. Nevertheless, capillary refill serves as a surrogate marker of perfusion in both simulated and human patients and interprovider assessment of capillary refill lacks reliability [ ]. The novel representation of perfusion provided through PediSepsisAR provides visual information of the simulated patient’s condition that participants would otherwise not receive. We connect this to our observation that PediSepsisAR participants had overall shorter times to fluid bolus administration, suggesting that AR representation of simulated patient perfusion may have affected the speed of fluid administration.A key balancing metric from our poststudy questionnaire is that more than 32% (8/25) of the participants in the PediSepsisAR group found the app distracting. Some participants reported in free-text comments that they had difficulty toggling between viewing digital media through the HoloLens and the physical monitor displaying vital signs, which was positioned beside the mannequin. Most of our participants had engaged in simulated septic shock scenarios before but had no previous experience with AR. It is possible that their lack of familiarity with the experience of visualizing digital media in the physical world contributed to their assessment of PediSepsisAR as distracting. Yet, it is important to consider not only the potential benefits but also the disadvantages of incorporating additional technology into an already effective educational practice such as high-fidelity simulation. It is also possible that certain learners would benefit more from AR-based educational strategies than others, which could be explored in future studies.
Limitations
This study has several important limitations. First, we address the limitations of assessing the feasibility of collecting data on the timing and volume of fluid administration with and without PediSepsisAR. Our fluid measurement system, though novel, also has limitations. In this feasibility study, we measured the timing and volume of fluid administration using a potentiometer embedded in a syringe. Because these measurements are based on the movement of the potentiometer and not on the actual volume of fluid administered, the air within the syringe could affect the measurements. It is possible that the fluid administration times for some participants were falsely shortened as a result.
Regarding generalizability, the cost of AR app development and head-mounted displays such as the HoloLens may hinder replicating the design of an AR model of circulation and its integration into a simulation. The potentiometer that we used to measure the timing and volume of fluid administration required engineering expertise. In addition, learning how to use and troubleshoot PediSepsisAR required time investment and technological support from our colleagues at BrickSimple. Therefore, lack of protected time for educational innovation, staffing constraints, and lack of funding for adequate support can all be potential roadblocks to replicate our study in other environments.
Second, we address the limitations of evaluating PediSepsisAR as an educational tool. The limited field of view provided by the first-generation HoloLens used in this study could have negatively affected participants’ experiences during the simulation. In particular, suspension of disbelief becomes more challenging as participants experience technology glitches during simulated exercise. Future studies displaying AR app through the HoloLens may benefit from using the second-generation HoloLens or the HP Mixed Reality headset, which have larger fields of view.
PediSepsisAR provides a simple representation of the complex pathophysiology of septic shock. With our available funding, we could integrate the CPReality prototype with the fluid administration system, but we were unable to make the perfusion model more realistic. There are many potential opportunities to make PediSepsisAR a more accurate representation of septic shock. These include, but are not limited to, adding a digital model of impaired capillary refill or skin findings such as mottling or petechiae. A more nuanced model could be configured to reflect improved or worsened perfusion depending on the type of shock (septic vs cardiogenic) and the participants’ chosen interventions. Specifically, an AR model of cardiogenic shock could depict impaired distal perfusion with a weakly pumping heart that pumps blood less effectively after the administration of fluids. Visualizing interactive AR models of both cardiogenic and septic shock alongside one another may allow participants to better recognize their differences and distinguish between the two during a simulated case of undifferentiated shock. Future studies should investigate AR models of septic and cardiogenic shock as educational tools to enhance simulation-based recognition of these pathologic states.
Conclusions
In conclusion, this randomized study demonstrated that it is feasible to measure the time to fluid bolus administration during pediatric septic shock simulation. Preliminary findings from our exploratory aims suggest that incorporating PediSepsisAR into septic shock simulation may enhance participants’ awareness of the simulated patient’s perfusion. Future studies can explore whether the addition of AR affects participant performance, including fluid administration, in septic shock simulation.
Acknowledgments
The authors would like to acknowledge the staff of the Center for Pediatric Resuscitation at the Children’s Hospital of Philadelphia for their support of this project.
Conflicts of Interest
BrickSimple, LLC, which employs JMB and AP, received compensation from the project funding described above for creating the augmented reality app described in this manuscript. ML has licensed intellectual property for virtual reality cardiopulmonary resuscitation applications. TPC has grant funding for research and development from Oculus/Facebook and is a medical advisor to A.i.Solv/i3 Simulations, which is not affiliated with this product or company in this manuscript.
Video 1 demonstrates the incremental expansion of digital circulation as participants administer fluid boluses during the simulation. The first expansion occurred after the administration of 20 cc/kg, the second at 40 cc/kg, and the final expansion at 60 cc/kg.
MOV File , 2096 KB
Prestudy questionnaire administered to all participants.
DOCX File , 15 KB
Poststudy questionnaire administered to participants in the PediSepsisAR group.
DOCX File , 14 KBReferences
- Kavanagh S, Luxton-Reilly A, Wuensche B, Plimmer B. A systematic review of virtual reality in education. Themes Sci Technol Educ 2017;10(2):85-119 [FREE Full text]
- Barsom EZ, Graafland M, Schijven MP. Systematic review on the effectiveness of augmented reality applications in medical training. Surg Endosc 2016 Oct;30(10):4174-4183 [FREE Full text] [CrossRef] [Medline]
- Munzer BW, Khan MM, Shipman B, Mahajan P. Augmented reality in emergency medicine: a scoping review. J Med Internet Res 2019 Apr 17;21(4):e12368 [FREE Full text] [CrossRef] [Medline]
- Izard SG, Juanes JA, García Peñalvo FJ, Estella JM, Ledesma MJ, Ruisoto P. Virtual reality as an educational and training tool for medicine. J Med Syst 2018 Feb 01;42(3):50. [CrossRef] [Medline]
- Owens R, Taekman J. Virtual reality, haptic simulators,virtual environments. In: The Comprehensive Textbook of Healthcare Simulation. New York: Springer; 2013:233-253.
- Baum ZM, Lasso A, Ryan S, Ungi T, Rae E, Zevin B, et al. Augmented reality training platform for neurosurgical burr hole localization. J Med Robot Res 2019;04(03n04):1942001. [CrossRef]
- Pulijala Y, Ma M, Pears M, Peebles D, Ayoub A. Effectiveness of immersive virtual reality in surgical training-a randomized control trial. J Oral Maxillofac Surg 2018 May;76(5):1065-1072. [CrossRef] [Medline]
- Jud L, Fotouhi J, Andronic O, Aichmair A, Osgood G, Navab N, et al. Applicability of augmented reality in orthopedic surgery - a systematic review. BMC Musculoskelet Disord 2020 Feb 15;21(1):103 [FREE Full text] [CrossRef] [Medline]
- Stepan K, Zeiger J, Hanchuk S, Del Signore A, Shrivastava R, Govindaraj S, et al. Immersive virtual reality as a teaching tool for neuroanatomy. Int Forum Allergy Rhinol 2017 Oct;7(10):1006-1013. [CrossRef] [Medline]
- Ellington DR, Shum PC, Dennis EA, Willis HL, Szychowski JM, Richter HE. Female pelvic floor immersive simulation: a randomized trial to test the effectiveness of a virtual reality anatomic model on resident knowledge of female pelvic anatomy. J Minim Invasive Gynecol 2018;26(5):897-901. [CrossRef] [Medline]
- Uppot RN, Laguna B, McCarthy CJ, De Novi G, Phelps A, Siegel E, et al. Implementing virtual and augmented reality tools for radiology education and training, communication, and clinical care. Radiology 2019 Jun;291(3):570-580. [CrossRef] [Medline]
- Cerezo Espinosa C, Segura Melgarejo F, Melendreras Ruiz R, García-Collado Á, Nieto Caballero S, Juguera Rodríguez L, et al. Virtual reality in cardiopulmonary resuscitation training: a randomized trial. Emergencias 2019 Feb;31(1):43-46 [FREE Full text] [Medline]
- Leary M, McGovern SK, Chaudhary Z, Patel J, Abella BS, Blewer AL. Comparing bystander response to a sudden cardiac arrest using a virtual reality CPR training mobile app versus a standard CPR training mobile app. Resuscitation 2019 Jun;139:167-173. [CrossRef] [Medline]
- Nas J, Thannhauser J, Vart P, van Geuns R, Muijsers HE, Mol J, et al. Effect of face-to-face vs virtual reality training on cardiopulmonary resuscitation quality: a randomized clinical trial. JAMA Cardiol 2020 Mar 01;5(3):328-335 [FREE Full text] [CrossRef] [Medline]
- Tang KS, Cheng DL, Mi E, Greenberg PB. Augmented reality in medical education: a systematic review. Can Med Educ J 2020 Mar 16;11(1):e81-e96 [FREE Full text] [CrossRef] [Medline]
- Eckert M, Volmerg JS, Friedrich CM. Augmented reality in medicine: systematic and bibliographic review. JMIR Mhealth Uhealth 2019 Apr 26;7(4):e10967 [FREE Full text] [CrossRef] [Medline]
- Zackoff MW, Cruse B, Sahay RD, Fei L, Saupe J, Schwartz J, et al. Development and implementation of augmented reality enhanced high-fidelity simulation for recognition of patient decompensation. Simul Healthc 2021 Jun 01;16(3):221-230. [CrossRef] [Medline]
- Muangpoon T, Haghighi Osgouei R, Escobar-Castillejos D, Kontovounisios C, Bello F. Augmented reality system for digital rectal examination training and assessment: system validation. J Med Internet Res 2020 Aug 13;22(8):e18637 [FREE Full text] [CrossRef] [Medline]
- Rochlen LR, Levine R, Tait AR. First-person point-of-view-augmented reality for central line insertion training: a usability and feasibility study. Simul Healthc 2017 Feb;12(1):57-62 [FREE Full text] [CrossRef] [Medline]
- Jani P, Blood AD, Park YS, Xing K, Mitchell D. Simulation-based curricula for enhanced retention of pediatric resuscitation skills: a randomized controlled study. Pediatr Emerg Care 2019 Jul 11 (forthcoming). [CrossRef] [Medline]
- Mittiga MR, Geis GL, Kerrey BT, Rinderknecht AS. The spectrum and frequency of critical procedures performed in a pediatric emergency department: implications of a provider-level view. Ann Emerg Med 2013 Mar;61(3):263-270. [CrossRef] [Medline]
- Mittiga MR, Frey M, Kerrey BT, Rinderknecht AS, Eckerle MD, Sobolewski B, et al. The medical resuscitation committee: interprofessional program development to optimize care for critically ill medical patients in an academic pediatric emergency department. Pediatr Emerg Care 2021 Mar 01;37(3):167-171. [CrossRef] [Medline]
- Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Surviving Sepsis Campaign Guidelines Committee including the Pediatric Subgroup. Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2012. Crit Care Med 2013 Feb;41(2):580-637. [CrossRef] [Medline]
- Weiss SL, Peters MJ, Alhazzani W, Agus MS, Flori HR, Inwald DP, et al. Surviving sepsis campaign international guidelines for the management of septic shock and sepsis-associated organ dysfunction in children. Pediatr Crit Care Med 2020 Feb;21(2):e52-106. [CrossRef] [Medline]
- Cheng A, Brown LL, Duff JP, Davidson J, Overly F, Tofil NM, et al. Improving cardiopulmonary resuscitation with a CPR feedback device and refresher simulations (CPR CARES Study): a randomized clinical trial. JAMA Pediatr 2015 Feb;169(2):137-144. [CrossRef] [Medline]
- Yeung J, Meeks R, Edelson D, Gao F, Soar J, Perkins GD. The use of CPR feedback/prompt devices during training and CPR performance: a systematic review. Resuscitation 2009 Jul;80(7):743-751. [CrossRef] [Medline]
- Rutledge C, Walsh CM, Swinger N, Auerbach M, Castro D, Dewan M, Quality Cardiopulmonary Resuscitation (QCPR) leaderboard investigators of the International Network for Simulation-based Pediatric Innovation‚ Research‚Education (INSPIRE). Gamification in action: theoretical and practical considerations for medical educators. Acad Med 2018 Jul;93(7):1014-1020. [CrossRef] [Medline]
- Balian S, McGovern SK, Abella BS, Blewer AL, Leary M. Feasibility of an augmented reality cardiopulmonary resuscitation training system for health care providers. Heliyon 2019 Aug 2;5(8):e02205 [FREE Full text] [CrossRef] [Medline]
- Leary M, McGovern SK, Balian S, Abella BS, Blewer AL. A pilot study of CPR quality comparing an augmented reality application vs. a standard audio-visual feedback manikin. Front Digit Health 2020 Feb 28;2. [CrossRef]
- Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform 2009 Apr;42(2):377-381 [FREE Full text] [CrossRef] [Medline]
- Harris PA, Taylor R, Minor BL, Elliott V, Fernandez M, O'Neal L, REDCap Consortium. The REDCap consortium: building an international community of software platform partners. J Biomed Inform 2019 Jul;95:103208 [FREE Full text] [CrossRef] [Medline]
- Chang TP, Santillanes G, Claudius I, Pham PK, Koved J, Cheyne J, et al. Use of a novel, portable, LED-based capillary refill time simulator within a disaster triage context. Prehosp Disaster Med 2017 Aug;32(4):451-456. [CrossRef] [Medline]
- Shinozaki K, Jacobson LS, Saeki K, Kobayashi N, Weisner S, Falotico JM, et al. The standardized method and clinical experience may improve the reliability of visually assessed capillary refill time. Am J Emerg Med 2021 Jun;44:284-290. [CrossRef] [Medline]
Abbreviations
AR: augmented reality |
CPR: cardiopulmonary resuscitation |
PEM: pediatric emergency medicine |
REDCap: Research Electronic Data Capture |
VR: virtual reality |
Edited by G Eysenbach; submitted 03.05.21; peer-reviewed by M Zackoff, J Woods; comments to author 21.05.21; revised version received 13.07.21; accepted 28.07.21; published 06.10.21
Copyright©Regina L Toto, Ethan S Vorel, Khoon-Yen E Tay, Grace L Good, Jesse M Berdinka, Adam Peled, Marion Leary, Todd P Chang, Anna K Weiss, Frances B Balamuth. Originally published in JMIR Medical Education (https://mededu.jmir.org), 06.10.2021.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Medical Education, is properly cited. The complete bibliographic information, a link to the original publication on https://mededu.jmir.org/, as well as this copyright and license information must be included.